Process Gauges (Solfrunt 6)
Specifications
Size: 6 "
Case and Ring:
For Stem or Wall Mounting -
CAST ALUMINUM, BACK FLANGED CASE with threaded ring, black finish and BUNA-N pressure-relieving back (Figures 1901T, 1931T)
For Panel Mounting -
CAST ALUMINUM, FRONT FLANGED CASE with steel hinged ring with black finish and BUNA-N pressure-relieving back ( Figure 1903)
Window: Acrylic
Pointer: Black aluminum, micrometer adjustable with positive lock and black finish.
Dial: Aluminum with white background and black markings.
Movement: Geared Arc-Loc with components of corrosion resistant 300 series stainless steel. Movement can be removed for examination and cleaning without disturbing span and scale shape adjustments.
Bourdon Tube: Phosphor bronze/silver brazed; 316 SST/heliarc welded.
Connection: Brass, alloy steel, or 316 stainless steel, 1/2" ANPT standard (1/4" ANPT optional).
Ranges: 30" Hg. Vac.; 30" Hg. Vac.-0-15, 30, 60, 100, 150, 200, 300. 0-15, 30, 60, 100, 200, 300, 400, 600, 1000, 1500, 2300, 3500, 6000.
Accuracy: ± 0.5% of span (Grade 2A)
AMETEK U.S. Gauge Division, 900 Clymer Ave., Sellersville, PA 18960. Tel: 215-257-6531; Fax: 215-257-3058.